Weekly infection control compliance check covering sterilization, PPE, and surface disinfection.

compliance weekly anytime sterilization infection controlcompliance Dental Document

5 steps · about 35 minutes · published by Dental Document

Use this checklist in your practice

Add it to Practice Flow and it becomes yours to edit, assign and schedule. It will start generating on its cadence, so the work comes back on its own.

Add this checklist Browse more

The steps

01

Verify spore test results from this week

Check that all biological indicator (spore) test results came back negative.

5 min Required file upload
Why this matters

CDC requires weekly spore testing of all sterilizers. A positive result means potential sterilization failure.

How to do it

1. Locate this week's spore test results. 2. Verify all results are negative. 3. If positive, quarantine instruments and retest. 4. Document results.

02

Inspect sharps containers - replace if 3/4 full

Check all sharps containers in operatories and lab for fill level.

5 min Required
Why this matters

Overfilled sharps containers cause needlestick injuries. OSHA requires replacement at 3/4 capacity.

How to do it

1. Check each sharps container. 2. Replace any at 3/4 full. 3. Seal and label full containers. 4. Place in designated pickup area.

03

Audit hand hygiene compliance for the week

Observe and document hand hygiene practices across clinical staff.

10 min Required
Why this matters

Hand hygiene is the single most effective infection prevention measure. Compliance monitoring improves behavior.

How to do it

1. Observe 3-5 patient interactions. 2. Note hand washing before/after gloving. 3. Check soap/sanitizer dispenser levels. 4. Document observations.

04

Check autoclave maintenance log and clean unit

Review autoclave cycle logs for the week and perform weekly cleaning.

10 min Required
Why this matters

Routine maintenance extends autoclave life and ensures consistent sterilization.

How to do it

1. Review all cycle logs for errors. 2. Clean chamber with approved cleaner. 3. Check door gasket for wear. 4. Run empty test cycle.

05

Verify waterline testing results meet standards

Check that dental unit waterline testing shows < 500 CFU/mL.

5 min Required value entry
Why this matters

CDC recommends dental unit waterlines maintain < 500 CFU/mL. Testing ensures compliance.

How to do it

1. Review most recent waterline test results. 2. Verify all lines are below 500 CFU/mL. 3. If elevated, initiate shock treatment. 4. Retest after treatment.